Change Language
Send SMS
Send Inquiry
Vertical Autoclave Double Chamber Auto Cut
Vertical Autoclave Double Chamber Auto Cut

Vertical Autoclave Double Chamber Auto Cut

Vertical Autoclave Double Chamber Auto Cut Specification

  • Instruments Type
  • Sterilizing Equipment
  • Usage Type
  • Laboratory/Hospital
  • Display Type
  • Analog Pressure Gauge
  • Storage Instructions
  • Store in dry, clean area when not in use
  • Measurement Range
  • 15-20 psi (sterilization range)
  • Features
  • Double chamber, Automatic cut-off, Pressure gauge, Water level indicator, Locking lid
  • Function
  • Sterilization by moist heat under pressure
  • Frequency
  • 50 Hz
  • Accuracy
  • 2% for pressure
  • Equipment Type
  • Vertical Autoclave Double Chamber Auto Cut
  • Material
  • Stainless Steel (304/316 grade)
  • Condition
  • New
  • Technology
  • Electric Steam Sterilization
  • Portable
  • No, Floor Standing
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low
  • Operating Type
  • Semi-Automatic with Auto Cut-off
  • Use
  • Sterilization of laboratory and medical equipment
  • Power Source
  • Electric
  • Power Consumption
  • 2-3kW (typical)
  • Voltage
  • 220-230V AC, 50Hz
  • Dimension (L*W*H)
  • Approx. 600 x 600 x 1200 mm
  • Weight
  • Approx. 80-120 kg (varies by capacity)
  • Color
  • Polished Stainless Steel
  • Accessories Included
  • Stainless Steel Baskets/Racks, Power Cord, User Manual
  • Controller Type
  • Digital/Analog with Automatic Cut-Off
  • Timer
  • 0-60 Minutes, Adjustable
  • Safety Mechanism
  • Pressure Release Valve, Automatic Cut-Off, Gasket Release System
  • Installation Type
  • Floor Standing
  • Water Filling
  • Manual/Automatic (Depends on Model)
  • Heater Material
  • Nichrome Heater / Immersion Type
  • Insulation
  • Glass Wool Around Chamber
  • Drain Valve
  • Provided for Easy Cleaning
  • Chamber Shape
  • Cylindrical Vertical
  • Lid Type
  • Radial Locking System with Pressure Seal
  • Temperature Range
  • Up to 134C
  • Gasket Type
  • Silicon Rubber Gasket
  • Chamber Material
  • Stainless Steel, Corrosion Resistant
  • Sterilization Cycle Time
  • 25-45 Minutes (Depending on Load)
  • Chamber Capacity
  • 30 to 150 Liters
 
 

About Vertical Autoclave Double Chamber Auto Cut

Vertical Autoclave Double Chamber Auto Cut

Double drum single stainless steel chamber with heavy aluminium lid, double safety valves to ensure the safety of the user and the pressure gauge on the top of the lid, rubber gasket placed well between the lid and the unit, release valve of the steam while the cycle complete, Water outlet valve and Two metal handle to hold the unit while movement.

This Autoclave is specially designed for meeting the requirement of General Surgery, Gynecology and Orthopedic surgeries.

Size: 12" x 20"

Heating Coil: 2KW

MOS: Stainless Steel 

Specification

MODEL

15

24

35

41

Size - Internal

12 Dia x 20 Depth

16 Dia x 24 Depth

20 Dia x 28 Depth

22 Dia x 30 Depth

Construction of Chamber

S.S. 304

S.S. 304

S.S. 304

S.S. 304

Capacity

35 Liters

75 Liters

150 Liters

175 Liters

Power Consumption

3000 Walts

4000 Walts

6000 Walts

9000 Walts

Operating Pressure

1.2 Kg

1.2 Kg

1.2 Kg

1.2 Kg

Operating Temperature

121°C

121°C

121°C

121°C

Voltage

230 Volt

230 Volt

440 Volt

440 Volt

Control

Digital

Digital

Digital

Digital




Superior Build for Consistent Sterilization

Crafted from polished stainless steel (304/316), the vertical autoclave delivers corrosion resistance and long-lasting performance. The double chamber design and precision gasket ensure a reliable pressure seal, while glass wool insulation maintains temperature uniformity throughout the sterilization cycle, enhancing efficiency and safety.


User-Friendly Operation with Enhanced Safety

This autoclave features semi-automatic controls with an intuitive analog or digital interface. Safety systems include an automatic cut-off, a silicon rubber gasket, a pressure release valve, and radial locking for the lid. The system automatically manages the sterilization process to prevent overheating and pressure buildup, ensuring protection for users and equipment.


Versatile Applications Across Laboratories and Hospitals

With chamber capacities ranging from 30 to 150 liters, this autoclave is ideal for sterilizing surgical instruments, laboratory glassware, and medical tools. Suitable for both hospitals and laboratory facilities, it supports rigorous, high-frequency use and is supplied with stainless steel racks and baskets for organized processing.

FAQs of Vertical Autoclave Double Chamber Auto Cut:


Q: How does the Vertical Autoclave Double Chamber Auto Cut ensure effective sterilization?

A: The autoclave uses electric steam sterilization, creating high-pressure, moist heat within the stainless steel cylindrical chamber. With an adjustable timer (060 min), a temperature range up to 134C, and chamber capacities between 30 and 150 liters, it reliably eliminates bacteria and pathogens from medical and laboratory equipment.

Q: What safety mechanisms are included in this autoclave?

A: Safety features include a pressure release valve, automatic cut-off controller, gasket release system, and a radial locking lid with a pressure seal. These mechanisms prevent excessive pressure buildup and temperature, protect users from accidental burns, and ensure safe operation throughout each sterilization cycle.

Q: When should I use the manual versus the automatic water filling option?

A: The water filling method depends on the specific model: some models allow manual filling, while others are equipped for automatic refilling. Choose manual filling for smaller, occasional loads, and use the automatic feature in high-throughput scenarios to save time and increase workflow efficiency.

Q: Where is this autoclave most effectively used?

A: It is ideally suited for hospitals, research laboratories, clinics, and pharmaceutical manufacturing facilities. The robust construction and high capacity make it especially effective in environments requiring frequent sterilization of diverse instruments.

Q: What is the process for cleaning and maintaining the autoclave?

A: Routine cleaning involves draining residual water using the provided valve and wiping down the chamber with a non-abrasive cleaner. Regularly check gaskets, pressure release valves, and all seals for wear. Always store the equipment in a dry, clean area when not in use to preserve performance and lifespan.

Q: How does the double chamber design benefit users?

A: The double chamber design allows more efficient heat distribution and faster cycle times (2545 minutes depending on load), accommodating higher instrument volumes. This improves throughput and reduces downtime, especially beneficial in busy medical and laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in AUTOCLAVE & HOSPITAL STEEL ITEMS Category

Air Curtain

Air Curtain

Minimum Order Quantity : 1 Piece

Condition : New

Use : Prevention of dust insects and pollutants

Features : Energy Efficient Durable Easy Installation

Function : Air Barrier Creation

Power Source : Electric

RAR Inbuilt

RAR Inbuilt

Minimum Order Quantity : 1 Piece

Condition : New

Use : Surgical/Medical

Features : Inbuilt design

Function : Wallmounted surgical functionality

Power Source : Other, Unknown

Ultrasonic Cleaning System Precision Metal Cleaning System

Ultrasonic Cleaning System Precision Metal Cleaning System

Condition : New

Use : Precision Metal Cleaning

Features : Highefficiency Ultrasonic Transducers, Digital Timer, Temperature Control, Heavy Duty Construction, Drain Valve

Function : Removes Oil, Grease, Dust, Contaminants through Ultrasonic Cavitation

Power Source : Electric

Syrring Needle Burner & Cutter MICO

Syrring Needle Burner & Cutter MICO

Condition : New

Use : Disposal of needles and syringes

Features : Burning and cutting of syringe needles; Ensures safety

Function : Burns and cuts syringe needles for safe disposal

Power Source : Other, Electricity