Change Language
  
Call Me Free
Send SMS
Send Inquiry
OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14
OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14

OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14

MOQ : 100 Pieces

OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14 Specification

  • Material
  • Aluminium Reflector and Metal Dome
  • Treatment Type
  • General Surgery, Specialized Medical Procedures
  • Accuracy
  • Consistent Intensity with Focusing
  • Automation Grade
  • Manual Focusing and Positioning
  • Frequency
  • 50 Hz
  • Product Type
  • OT Light (Operation Theater Light)
  • Properties
  • Shadowless, High Intensity, Adjustable
  • Suitable For
  • Hospitals, Clinics, Medical Institutes
  • Function
  • Illumination for Medical Operation
  • Application
  • Operation Theatre Illumination
  • Temperature Range
  • 0C to 50C Operating Range
  • Phase
  • Single Phase
  • Weight
  • Approx. 11 kg per dome
  • Height
  • Adjustable Suspension (Ceiling Mount)
  • Dimension (L*W*H)
  • Each Dome: Approx. 14-inch Diameter
  • Humidity Range
  • 0-90% RH (Non-condensing)
  • Shape
  • Double Dome Round
  • Color Code
  • White (Powder-Coated)
  • Power
  • 150 W (2 x 150 W for each dome)
  • Use
  • Surgical Lighting/Medical Procedures
  • Display
  • No Digital Display
  • Power Source
  • Electric (Ceiling Mounted)
  • Voltage
  • 220 V AC
  • Color Temperature
  • 4000-4500 K
  • Light Adjustment
  • Step-less Intensity Control
  • Rotation
  • 360 Dome and Arm Rotation for Positioning
  • Mount Type
  • Ceiling Mounted
  • Light Intensity
  • Up to 80,000 Lux per dome
  • Number of Domes
  • 2 (Double Dome Configuration)
  • Cooling Mechanism
  • Air Vents for Halogen Cooling
  • Reflector Type
  • Aluminium Parabolic Reflector
  • CRI (Color Rendering Index)
  • 90 Ra
  • Life Span of Bulb
  • 2000 Hours (Typical)
  • Bulb Type
  • Halogen
  • Focusing
  • Manual Focusing by Sterile Handle
  • Sterilizable Handle
  • Provided for Safety
  • Backup Facility
  • Can support UPS/Inverter supply
 

OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14 Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Supply Ability
  • 1000 Pieces Per Month
  • Delivery Time
  • 3 Days
 

About OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14



Experience enviable illumination with the OT Light Aluminium Reflector Halogen Ceiling 2 Dome 14, crafted for elite performance in rigorous medical environments. This top-notch double dome configuration boasts aluminium parabolic reflectors delivering up to 80,000 Lux per dome, ensuring shadowless, high-intensity lighting ideal for surgical procedures. With competitive pricing and a reputation for being top-ranking among medical lights, this model offers 360 dome and arm rotation, manual sterile focusing, step-less intensity control, and secure backup. Get it now for hospitals, clinics, or medical institutes seeking reliable surgical lighting solutions with a CRI 90 Ra.

Premium Material, Versatile Use & Advanced Features

The OT Light Aluminium Reflector Halogen Ceiling 2 Dome 14 is engineered with a durable aluminium reflector and powder-coated metal dome, embodying exceptional build quality. Used extensively across operation theatres for general surgery and specialized medical procedures, it features enviable shadowless lighting, manual sterile handle focusing, and 360 rotation for absolute positioning flexibility. Its high CRI guarantees precise color rendering, making it the elite choice for surgical excellence in hospitals, clinics, and institutes.


Delivery Timelines & Payment with Assurance

Order the OT Light Aluminium Reflector Halogen Ceiling 2 Dome 14 and benefit from secure shipping across Indias main domestic market. The estimated delivery time is communicated at purchase, ensuring timely arrival for your facilitys needs. With transparent outlay structures and trusted payment termsincluding advance and digital optionsprocurement is as straightforward as the product is dependable. Obtain a precise estimate and streamline installation with our reliable logistic support, tailored to medical professionals.


FAQs of OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14:


Q: How does the manual focusing mechanism work for the OT Light Alluminium Reflactor Halogen Ceiling 2 Dome 14?

A: The manual focusing can be adjusted using the sterilizable handle, allowing medical staff to easily direct and focus the light for optimal illumination during surgery or procedures.

Q: What are the main benefits of the double dome configuration in this OT light?

A: The double dome setup provides broad, shadowless illumination over a larger surgical area, ensuring precise visibility and reducing the risk of obstructed light during operations.

Q: When should the halogen bulbs typically be replaced?

A: Halogen bulbs in the OT Light have an estimated typical life span of 2,000 hours. Replacement is recommended when light intensity decreases noticeably or after reaching the rated lifespan.

Q: Where is the OT Light Aluminium Reflector Halogen Ceiling 2 Dome 14 most suitably installed?

A: This light is best suited for ceiling-mounted installations in hospitals, clinics, or medical institutesspecifically in operation theatres for surgical and specialized medical procedures.

Q: What is the process for adjusting the lights intensity and positioning?

A: Light intensity is adjusted seamlessly using the step-less control feature, while dome and arm can be rotated 360 and focusing tuned manually via the sterilizable handle for precise targeting.

Q: How does the light maintain consistent performance during power interruptions?

A: The OT Light can connect to a UPS or inverter supply, providing reliable backup so surgical procedures can proceed uninterrupted during brief power outages.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Operation Theater Light Category

Analiser Lamp

Analiser Lamp

Minimum Order Quantity : 100 Pieces

Power Source : Electric

Application : Laboratory Analysis, Industrial Measurement

Material : Polycarbonate, Glass

Shape : Tubular

Color Code : White

Lamp Holders

Lamp Holders

Minimum Order Quantity : 100 Pieces

Power Source : AC

Application : For holding bulbs in lighting fixtures

Material : Bakelite / Polycarbonate / Brass

Shape : Round

Color Code : White / Black / Brown

Multiple Facet Light

Multiple Facet Light

Minimum Order Quantity : 100 Pieces

Power Source : Electric

Application : Industrial, Architectural Lighting

Material : HighGrade Polycarbonate

Shape : Multifaceted

Color Code : Clear / White

OT Light Glass Reflactor Halogen Ceiling

OT Light Glass Reflactor Halogen Ceiling

Minimum Order Quantity : 100 Pieces

Power Source : Electric

Application : Hospital

Material : Mild Steel

Shape : Round



Back to top