Hysteroscopy Specification

  • Use
  • Used for visualizing and treating intrauterine disorders
  • Treatment Type
  • Hysteroscopic surgery and diagnostics
  • Application
  • Gynecological examination and surgery
  • Suitable For
  • Hospitals, clinics, IVF centers
  • Accuracy
  • High optical clarity
  • Shape
  • Rod shaped
  • Temperature Range
  • Operative temperature: 15C - 40C
  • Phase
  • Single Phase
  • Weight
  • Lightweight (approx. 600g)
  • Properties
  • Corrosion resistant, high precision optics
  • Humidity Range
  • Up to 85% RH
  • Dimension (L*W*H)
  • As per standard medical instrument size
  • Height
  • Standard instrument length
  • Function
  • Diagnostic and operative hysteroscopic procedures
  • Product Type
  • Medical Endoscopy Device
  • Display Type
  • External display
  • Automation Grade
  • Manual
  • Power
  • Manual (no direct power required)
  • Color Code
  • Silver
  • Material
  • Stainless Steel
  • Display
  • Compatible with external medical monitors
  • Endoscope Type
  • Rigid
  • Compatible Accessories
  • Sheath, fiber optic cable, camera head
  • Surface Finish
  • Matte/Satin for anti-glare
  • Leakage Test Pressure
  • Up to 2 bar
  • Light Transmission
  • Fiber optic cable compatible
  • Field of View
  • 80 (typical)
  • Working Channel Diameter
  • 2 mm (if integrated)
  • Connector Type
  • Standard endoscopic light connector
  • Angle of View
  • 30 (typical)
  • Sterilization Method
  • Autoclavable up to 134C
 
 

About Hysteroscopy

Hysteroscopy:- 

Working Element

Gynaecological resectoscopes utilize a passive spring mechansim . The Electrode inside the sheth in the restimg position advance past the sheth against the spring and then returns to the sheth (During Cutting) by the force of spring .

Electrical Current Should be applied to the electrod when the operative site is completelely visualised and the electrode is returning to the Sheth .

 




High Precision Visualization

Our hysteroscope provides outstanding optical clarity for guided gynecological diagnosis and operative procedures. The 30 angle and 80 field of view enable comprehensive inspection of the uterine cavity, ensuring precise treatment and enhanced patient outcomes in clinics and hospitals.


Designed for Durability and Hygiene

Manufactured from high-quality stainless steel with a matte/satin finish, this instrument is corrosion resistant and supports repeated sterilization at up to 134C. The autoclavable construction and standard leakage test ensure long-term use and patient safety in diverse healthcare settings.


Versatile and Easy Integration

This rigid hysteroscope comes with a standard endoscopic light connector, making it compatible with various medical-grade monitors, sheath systems, and fiber optic cables. Its lightweight and ergonomic rod-shaped design promotes ease of handling during both diagnostic and operative hysteroscopic interventions.

FAQs of Hysteroscopy:


Q: How is the hysteroscope sterilized for repeated medical use?

A: The hysteroscope can be fully sterilized via autoclave, tolerating temperatures up to 134C. This ensures effective disinfection between uses, supporting strict infection control protocols in hospitals and clinics.

Q: What is the typical process for using this hysteroscope in clinical procedures?

A: The hysteroscope is introduced into the uterine cavity, allowing visualization and treatment of intrauterine conditions. It is compatible with external monitors, sheaths, and fiber optic cables, providing high-quality imaging for both diagnostics and operative interventions.

Q: When should this type of hysteroscope be used?

A: This rigid hysteroscope is ideal for both diagnostic and surgical hysteroscopic procedures, particularly in gynecological assessments, treatment of intrauterine disorders, and fertility evaluations. It is suitable for use in hospitals, clinics, and IVF centers.

Q: Where can this hysteroscope be effectively utilized?

A: Designed for professional medical environments, this instrument is well-suited for use in operating rooms, outpatient procedure rooms, and fertility clinics across hospitals and healthcare centers.

Q: What are the benefits of using a 30 angle of view and an 80 field of view?

A: A 30 angle of view provides an optimal perspective to visualize the uterine cavity thoroughly while the 80 field of view ensures broader coverage, enabling clinicians to examine and treat a wide range of intrauterine pathology efficiently.

Q: How does the matte/satin surface finish benefit clinical practice?

A: The matte/satin finish is designed to be anti-glare, reducing unwanted reflections during procedures and improving the clarity of the optical field for physicians conducting hysteroscopic surgeries or diagnostics.

Q: What compatible accessories are recommended for this hysteroscope?

A: Recommended accessories include compatible sheaths for safe access, fiber optic cables for brilliant illumination, and a camera head for advanced video monitoring. These enhance procedural effectiveness and workflow during hysteroscopic examinations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laparoscopy Setup Category

Alpha Fiator

Alpha Fiator

Product Type : Electrosurgical Unit

Application : Surgical Procedures

Shape : Rectangular

Use : Cutting and Coagulation

Suitable For : Hospital and Clinic Use

Automation Grade : SemiAutomatic

Luma Monitors

Luma Monitors

Product Type : Monitor

Application : Professional video monitoring HD/SD applications multiple input configurations

Shape : Rectangular

Use : Ideal for video production broadcasting and professional applications

Suitable For : Highdefinition and standarddefinition applications

Automation Grade : Manual

Clip Application

Clip Application

Product Type : Clip Applicator

Application : Hospital

Port Closure Needle

Port Closure Needle

Product Type : Surgical Instrument

Application : Medical Use for Port Closure during surgical procedures

Shape : Needle and Clamp

Use : Reusable

Suitable For : Laparoscopic Surgery

Automation Grade : Manual



Back to top