Autoclave Hi-Pressure Triple Wall Radial Locking
Autoclave Hi-Pressure Triple Wall Radial Locking

Autoclave Hi-Pressure Triple Wall Radial Locking

Autoclave Hi-Pressure Triple Wall Radial Locking Specification

  • Instruments Type
  • Vertical/Horizontal Autoclave
  • Usage Type
  • Industrial/Laboratory
  • Features
  • Radial locking lid, high pressure triple wall, digital temperature & pressure display, safety valve, pressure cutoff system, gasket release lever, water level indicator, energy efficient insulation
  • Frequency
  • 50 Hz
  • Storage Instructions
  • Store in clean, dry room, avoid exposure to corrosive chemicals
  • Accuracy
  • 1C (Temperature), 0.1 bar (Pressure)
  • Display Type
  • Digital (Temperature and Pressure)
  • Function
  • Sterilization through high-pressure saturated steam
  • Measurement Range
  • 121C to 135C (Temperature), up to 2.5 bar pressure
  • Equipment Type
  • Laboratory Autoclave
  • Material
  • Stainless Steel (SS 304/316)
  • Condition
  • New
  • Technology
  • Radial Locking, Triple Wall Construction
  • Portable
  • No
  • Wall Mounted
  • No
  • Real-Time Operation
  • Yes
  • Noise Level
  • Low/Minimal
  • Operating Type
  • Automatic/Semi-Automatic
  • Use
  • Sterilization of laboratory equipment and instruments
  • Power Source
  • Electric
  • Power Consumption
  • 2-6 kW (depending on model)
  • Voltage
  • 220-240V, 50Hz
  • Dimension (L*W*H)
  • Varies with model (e.g., 400x600mm, 550x900mm for DiaxDepth)
  • Weight
  • Approx. 70-300 kg depending on size
  • Color
  • Stainless Steel finish (Silver/Grey)
  • Chamber Capacity
  • 35, 50, 75, 100, 150, 200 liters (as per model)
  • Loading Orientation
  • Vertical/Horizontal loading (as per model)
  • Safety Features
  • Automatic pressure release, over-temperature cut-off, automatic low-water cutoff, safety valves
  • Chamber Design
  • Triple wall, insulated
  • Lid Locking Mechanism
  • Radial locking with pressure interlock for added safety
  • Temperature Control
  • Microprocessor based digital controller
  • Fittings & Accessories
  • Heater, perforated basket, drainage valve, power cable, outer handle for easy movement
  • Surface Finish
  • Mirror polish outside, matt finish inside
  • Company/Brand
  • Custom/Manufacturer Specific
  • Pressure Gauge
  • Bourdon type analog pressure gauge standard
 
 

About Autoclave Hi-Pressure Triple Wall Radial Locking

Autoclave Hi-Pressure Triple Wall Radial Locking

 Size (L x B x H) : 250 x 450 mm, 300 x 500 mm, 350 x 550 mm, 450 x 600 mm, 550 x 700 mm.

Autoclave Triple Wall Hi-Pressure Outer body made of think mild steel finished with powder coating paint or S.S. both the chamber & inner Jacket made of thick stainless steel. The lid made of stainless steel. The equipment is absolutely pressure leak proof. The lid is tightened by radial arms through a steering wheel, provided with pressure gauge, pressure release valve, safety valve, water valve indicator. Equipment is provided with a pedal lifting arrangement. The Autoclave can hold the pressure in between 5 to 20 PSI. Provided with s.s.basket, Pressure switch & automatic low water level cut off device.

The Triple Wall Autoclave is also available in Wing Nuts type model

     

 



Advanced Chamber Design

The triple-wall construction provides superior insulation and ensures durable, long-lasting performance. Each chamber, crafted from high-grade stainless steel (SS 304/316), ranges in capacity, catering to diverse sterilization needs. The mirror-polished exterior and matt-finished interior enhance corrosion resistance and maintain hygiene standards, crucial for laboratory applications.


Radial Locking with Pressure Interlock

Experience secure operation with the radial locking lid mechanism, which includes a pressure interlock feature. This innovative design eliminates accidental opening under pressure, maximizing user safety during high-pressure steam cycles. The autoclaves ergonomic handles and digital display make daily usage convenient and intuitive.


Precision Control and Enhanced Safety

Equipped with a microprocessor-based digital controller, this autoclave delivers real-time temperature and pressure monitoring with high accuracy (1C temperature, 0.1 bar pressure). Integrated safety systems, such as automatic release valves and over-temperature cut-off, guarantee safe, error-free function, supporting both automatic and semi-automatic processes.

FAQs of Autoclave Hi-Pressure Triple Wall Radial Locking:


Q: How does the triple-wall chamber design improve sterilization efficiency?

A: The triple-wall construction offers superior thermal insulation, promoting uniform heat distribution and retention during the sterilization process. This results in consistent, energy-efficient operation and effective elimination of contaminants, especially vital in laboratory settings.

Q: What is the benefit of the radial locking lid with pressure interlock?

A: The radial locking mechanism, combined with pressure interlock, ensures the lid remains securely closed during high-pressure operation. This feature significantly enhances operator safety by preventing accidental opening while the chamber is pressurized.

Q: When should the autoclave be used for laboratory sterilization?

A: The autoclave is ideally used whenever laboratory equipment or instruments require sterilization, before and after experiments, or during regular lab maintenance. Its real-time operation and digital controls allow flexible scheduling to meet varied sterilization needs.

Q: Where should the autoclave be installed for optimal performance and safety?

A: For best results, install the autoclave in a clean, dry laboratory environment with adequate ventilation and easy access to electrical outlets. Avoid areas exposed to corrosive chemicals to protect the stainless steel finish and internal components.

Q: What process does the autoclave use for sterilization?

A: This equipment employs high-pressure saturated steam within the chamber, reaching temperatures of 121C to 135C and up to 2.5 bar pressure. The steam effectively eradicates microorganisms and contaminants on laboratory instruments and glassware.

Q: How do the digital temperature and pressure controls assist in usage?

A: The microprocessor-based controller enables precise monitoring and adjustment of both temperature and pressure, ensuring accurate sterilization cycles. Digital displays provide real-time status updates, facilitating easy operation and compliance with laboratory protocols.

Q: What are the key safety features included in this autoclave model?

A: Major safety features include automatic pressure release, over-temperature cut-off, automatic low-water cutoff, safety valves, and a pressure cutoff system. These mechanisms safeguard users and equipment by preventing malfunction and hazardous situations.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in AUTOCLAVE & HOSPITAL STEEL ITEMS Category

Syrring Needle Burner & Cutter MICO

Syrring Needle Burner & Cutter MICO

Use : Disposal of needles and syringes

Features : Burning and cutting of syringe needles; Ensures safety

Color : White and Red

Function : Burns and cuts syringe needles for safe disposal

Portable : Yes

Autoclaves Aluminium 'P' Type

Autoclaves Aluminium 'P' Type

Minimum Order Quantity : 1 , , Piece

Use : Sterilization

Features : Pressure gauge Handles for portability

Color : Silver

Function : Sterilization of medical/lab equipment

Portable : Yes

Syrring Needle Burner & Cutter AASTHA

Syrring Needle Burner & Cutter AASTHA

Use : Medical waste disposal

Features : Efficient needle burning and cutting compact design low noise

Color : Silver

Function : Burning and cutting syringe needles

Portable : Yes

Hospital Steel Items Shoe Cover Dispenser

Hospital Steel Items Shoe Cover Dispenser

Use : Hospital

Features : Durable Compact Easy to Use

Color : Steel Finish

Function : Dispensing Shoe Covers

Portable : Yes